Home Products Regulators & Reducers Life Support: Oxygen Pressure Reducer

Life Support: Oxygen Pressure Reducer

Send this page to someone print icon

     

    Part No. B43575-1
    Oxygen Pressure Reducer

  • Lightweight, compact design
  • High flow
  • Precise pressure control
  • Integral pressure transducer
  • Integral fill/check valve

Application:

Carleton's Oxygen Pressure Reducer is an integral part of a gaseous aircraft emergency passenger oxygen system. The valve mounts directly to the cylinder and hand valve, and
provides a regulated pressure supply to an altitude compensated Centralized Flow Control Unit for distribution to the passenger masks.

Carleton's Oxygen Pressure Reducer (part number B43575-1) has been qualified for use on many commercial aircraft.

Features:

This compact, lightweight, single-stage pressure reducer uses a balanced piston design to provide precise pressure control, low leakage and high flow capacity. The outlet pressure is tightly controlled between 115 and 145 psig over an inlet range of 200 to 2,175 psig with a flow capacity of 0 to 504 slpm (NTPD). The design and construction of the valve maximizes oxygen safety. The reducer is equipped with a fill port, an outlet check valve, and a pressure transducer.

Specifications:    
Weight 2.31 lbs (1.05 Kg)
Inlet Pressure

200 to 2,000 psig (14 to 150 barg)
Outlet Pressure 115 to 145 psig (7.9 to 10 barg)
Flow Rate 0 to 504 slpm  
Transducer
Power Supply
8 to 16 VDC  
Transducer Output
Signal
4 to 20 mA
Media Gaseous Oxygen per MIL-PRF-27210
     
Operating Environment:  
Operating Temperature 5 to 158 deg F (-15 to 70 deg C)
Storage Temperature -67 to 185 deg F (-55 to 85 deg C)
Shock 9 g sustained
20 g crash
 
Vibration 5.83 Grms each axis  
Humidity 0 to100% relative humidity
Altitude 41,000 ft max (12,497 m)
     
Product Interfaces :  
Inlet Port CGA540
(.903 - 14NGO RH int thread)
Outlet Port MS33514-8
Fill Port MS 33514-5
Electrical Connector ASN0053010B6PNH
ASNE0053R10B6PNH

Product Datasheet - PDF
B43575-1 Oxygen Pressure Reducer

B44585-1 Oxygen Pressure Reducer


© 2008 Carleton Technologies Inc.
Part of the Cobham Life Support Division
10 Cobham Dr. Orchard Park, NY 14127