Home Products Regulators & Reducers Life Support: Electro-mechanical Valve & Regulator (EMVR)

Life Support: electro-mechanical Valve & Regulator (EMVR)

Send this page to someone print icon


Electro-mechanical Oxygen Mask Regulator
  • Compact design
  • Remotely actuated
  • Oxygen service
    to 2,000 psi
  • Multi-functional
    device

Application:

The EMVR (part number B47875) is an integrated on/off valve-pressure regulator that is electrically actuated from a remote location such as the cockpit of an airplane. The EMVR is
adaptable to a variety of high pressure applications.

Features:

The cylinder mounted integrated on/off valve-pressure regulator provides an outlet pressure of 75 ± 9 psig from an inlet of 150 / 1,850 psig. The EMVR is compact and its fully integrated design allows for multiple functions from a single component. Over pressure-protection of the system downstream is provided by a relief valve set at 89 ± 5 psig. A pressure transducer provides an output signal of 4 / 20 mA for remote indication of the bottle pressure. A simple cockpit mounted switch allows for remote shutoff of the oxygen at the high pressure source. Valve position indication provides feedback after the valve has been toggled open or closed.

The valve can be supplied with a fill/check valve for system charging. The valve incorporates a restrictor to limit the charging rate for temperature stabilization, and an automatic shutoff feature to limit system pressure to 2,150 psig.

Specifications:    
Medium Oxygen
Inlet Pressure 150 to 1850 psig 10.3 to 127.6 bar)
Outlet Pressure 73 +/- 9 psig (5.0+/- 0.6 bar)
 
Proof Pressure    
 Inlet Port 3,263 psig (225.0 bar)
 Recharge Port 3,263 psig (225.0 bar)
 Outlet Port 188 psig (12.9 bar)
 
Burst Pressure    
 Inlet Port 6,290 psig (433.7 bar)
 Recharge Port 6,290 psig (433.7 bar)
 Outlet Port 250 psig (17.3 bar)
 
Flow 0 to 320 slpm
External Leakage .0001 slpm
Internal Leakage .001 slpm
Weight 3.4 lb max (1.5 kg max)
 
Operating Environment:  
Temperature 0 to 158 deg F (-18 to 70 deg C)
Vibration 5.8 grms @ 10 to 250 Hz
Shock 20 g for 11 ms
Cycles 10,000 cycles
 
Non-Operating Environment:  
Temperature -65 to 185 deg F (-54 to 85 deg C)
 
Electrical Requirements:  
Operating Voltage 28 +4 / -10 Vdc
Operating Current 1 A
 

Product Datasheet - PDF
Electro-mechanical Oxygen Mask Regulator


Commercial Aircraft

Life Support Products
  Pneumatic Products


© 2008 Carleton Technologies Inc.
Part of the Cobham Life Support Division
10 Cobham Dr. Orchard Park, NY 14127